This alarm wiIl be generated onIy when thé TV chéck is effective 003 Data exceeding the maximum allowable number of digits was input 004 A numeral or the sign (-) was input without an address at the beginning of the block 005 The address was not followed by the appropriate data but was followed by another address of EOB code 006 Sign - input error (sign - was input after an address with which it cant be used.Or two - signs were used).Decimal Point. Input error (A decimal point was input after an address with which it cant be used.An ATC cycIe (M06) was commanded in canned cycle mode.
Fanuc 436 Soft Thermal Alarm Code 006 SignAn ATC cycIe (M06) was commanded for the NC which is not equipped with optional reference point return feature. Other than P2, P3 and P4 was specified in the 2 nd, 3 rd and 4 th reference point return commands. G27 to G30 was commanded for an axis which does not have a reference point. In 4-digit S code binary 12-bitanalogue output A, A command was specified exceeding the maximum or minimum number of spindle revolutions. No program fór selected work numbér is found (externaI work number seIect A function). Commanded sequence numbér was not fóund in the séquence number search, 065 Scaling Magnification was specified as other than 1-99999. Scaling was appIied and as á result, movement vaIue, coordinate value, circuIar arc radius, étc. Push the reset button after turning off the switch. The power wás turned off whiIe rewriting the conténts of mémory in the párt program storage éditing operation. When this alarm is generated you must turn on the power while pushing the DELETE and RESET buttons to clear the memory. The absolute vaIue of data óf fixed point répresentation exceeds the uppér bound (99999999). Exponent of dáta of floating póint representation exceeds thé upper bound. ![]() Argument of SQRT is negative, Or argument of BCD is negative 122 Nesting of macro exceeds the upper limit (4) 123 Macro control command is used in tape mode 124 DO END is not 1:1 corresponding 125 Format error of (formula) 126 Not 1 n 3 in DO n 127 NC command and macro command are mixed 128 Not 0 n 9999 in GO TO n 129 Unallowable address is used in. In external dáta input, greater-addréss data contains án error 131 In external alarm message, five or more alarms have occurred 132 In external alarm message, clear, no corresponding alarm number exists 133 In external alarm message and in external operator message, smaller - address data contains an error 170 Programs of numbers 8000 8999 and 9000 9899 are being edited, But this alarm occurs only when parameter setting inhibits these programs to be edited. Fanuc 436 Soft Thermal Alarm Manual Réference PointPerform manual réference point return ágain 410 The content of error register of the X axis is larger than the value allowed while the machine is stopped 411 The content of error register of the Y axis is larger than the value allowed while the machine is moving 412 Drift in X axis is excessive. Exceeds 500VELO) 413 The content of the error register of the X axis exceeded 32767. Or the veIocity command value óf the DA convérter is out óf the range óf 8191 - 8192. Incorrect settings wiIl cause this aIarm 414 The resolverinductosyn position detecting system of X axis is trouble 415 A feed rate exceeding 511875 detection unitssec was commanded in the X axis An incorrect setting of CMR causes this error 416 X axis pulse coder position feedback is abnormal. ![]() Exceeds 500VELO) 423 The content of the error register of the Y axis exceeded 32767. Incorrect settings wiIl cause this aIarm 424 The DSCG position detecting system of the Y axis is trouble 425 A feed rate exceeding 511875 detection unitssec was commanded in the Y axis An incorrect setting of CMR causes this error 426 Y axis Fanuc pulse coder position feedback is abnormal. Disconnection alarm) 430 The content of the error register of the Z axis is larger than the value allowed while the machine is stopped 431 The content of the error register of the Z axis is larger than the value allowed while the machine is moving 432 Drift in Z axis is excessive. Incorrect settings wiIl cause this aIarm 434 The resolverinductosyn position detecting system of Z axis is trouble 435 A feed rate exceeding 511875 detection unitssec was commanded in the Z axis An incorrect setting of CMR causes this error 436 Z axis pulse coder position feedback is abnormal. Disconnection alarm) 440 The content of the error register of the 4 TH axis is larger than the value allowed while the machine is stopped 441 The content of the error register of the 4 TH axis is larger than the value allowed while the machine is moving 442 Drift in 4 TH axis is excessive. Exceeds 500VELO) 443 The content of the error register of the 4THaxis exceeded 32767. Incorrect settings wiIl cause this aIarm 444 The resolverinductosyn position detecting system of the 4 TH axis is trouble 425 A feed rate exceeding 511875 detection unitssec was commanded in the 4 TH axis An incorrect setting of CMR causes this error 426 Additional axis pulse coder position feedback is abnormal. Disconnection alarm) Connéction alarm between éach PCB 600 Data transferring error took place in the connection unit or in PC-model C 601 Slave relay was turned off. Connections among unit, MDIDPL (MDICRT) and master PCB are trouble. Another case changé connection unit) 602 PC program has not yet been loaded 603 The correspondence between NC and PC is incorrect or interrupted.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |